Chapter 7. Applications
7-4 T3SU 300 User Manual 61200217L1-1
Table 7-2. Configuration Example for Multiport
Application
Local T3SU 300 Remote T3SU 300
Network
DS3 Framing - C-bit Parity DS3 Framing - C-bit Parity
Line Length - Short Line Length - Short
DS3 Timing - Loop DS3 Timing - Loop
Datalink - Enabled Datalink - Enabled
DTE 1 (HSSI)
Port State - Enabled Port State - Enabled
Nx75k blocks - 240 Nx75k blocks - 240
DTE 2 (HSSI)
Port State - Enabled Port State - Enabled
Nx75k blocks - 240 Nx75k blocks - 240
DTE 3 (V.35)
Port State - Enabled Port State - Enabled
Nx75k blocks - 80 Nx75k blocks - 80
DTE 4 (V.35)
Port State - Enabled Port State - Enabled
Nx75k blocks - 20 Nx75k blocks - 20
System
Local IP Address - 10.4.10.2
Nothing required. Remote unit
can be managed using the lo-
cal T3SU 300.
Management
Subnet Mask -
255.255.255.0
Gateway IP Address -
10.4.10.1
IP Security - Disabled
Trap IP Address - 10.4.10.10
Management Port - LAN