A SERVICE OF

logo

is
Instruction manual SGE 93
C04 (blocking error)
Appliance selection
error
Incorrect water heater
selection/Incorrect
selection resistor
1. Check whether the correct water heater is
selected (3.4.2 "General and electrical specifications").
2. If the correct water heater is selected, fit the correct selection
resistor.
3. If incorrect water heater selected, select the correct one.
If the error cannot be resolved or is persistent, contact your
installation engineer
To replace the necessary parts, you must contact your installation
engineer
C05 (blocking error)
Error message from the
solar controller.
Incorrect reference
voltage from the AD
converter.
EEPROM error
1. Reset controller.
2. Check that the frequency of the power supply is
compliant (3.4.2 "
General and electrical specifications"). If this
is not the case, contact your installation engineer.
3. If the frequency is correct but the error persists, replace the
solar controller.
If the error cannot be resolved or is persistent, contact your
installation engineer
To replace the necessary parts, you must contact your installation
engineer
E01 (blocking error)
The temperature
protection at the top of
the tank has been
activated.
The temperature of the
water at the top of the
tank is >88
o
C.
None. This is a temporary message that may appear from time to
time, but will disappear automatically.
E03 (lock-out error)
Error in temperature
sensor T
1
at the top of
the tank.
The two temperature
sensors in the tank
detect a difference of
> 10°C over a period of
at least 60 seconds.
1. Check sensor position and wiring.
2. Reset the controller if necessary. Replace the sensor if the error
persists.
To replace the necessary parts, you must contact your installation
engineer
E04 (lock-out error)
Defect in the dummy
sensor
(2)
.
The two temperature
sensors detect a
difference of >10
o
C
over a period of at least
60 seconds.
1. Check the wiring of the dummy 1 and dummy 2.
2. Reset the controller if necessary. Replace the dummy sensor if
the error persists.
To replace the necessary parts, you must contact your installation
engineer
(1) Temperature sensor T
1
is a 2-in-1 sensor; T
1
contains 2 NTCs for maximum thermostat and safety thermostat protection.
(2) The dummy flue gas sensor consists of dummy flue gas sensor 1 and dummy flue gas sensor 2.
Code + description Cause Measure Remark