A SERVICE OF

logo

20 en | Operation MIYN46 Wall Transmitter
970.035b | F.01U.278.521 | v2.0 | 2012.12 User Manual US Bosch Security Systems
6 Operation
6.1 Description of the six different states
During operation, the MIYN46 Wall Transmitter can be set to one of six following states:
Each state is indicated by the signal lamp and by a special position of the output relays.
It is possible to configure the MIYN46 Wall Transmitter in order that:
the Call for Assistance can be triggered only if the Care Personnel is present.
the device does not manage the Staff Presence. This mode makes sense only if the
output relays are not provided or not used.
The transition to a specific condition depends on the device configuration, of its actual condi-
tion and of the action completed; as shown on the charts in the following chapters.
State Description
Stand-by No call is being processed.
Alarm without staff presence The resident has triggered a Call for Help but the Care
Personnel has not yet responded.
Alarm with staff presence The Care Personnel has responded after a Call for Help.
Assistance without staff presence A Call for Assistance has been triggered without the
presence of the Care Personnel.
Assistance with staff presence A Call for Assistance has been triggered in the presence
of the Care Personnel.
Staff Presence without alarm The Care Personnel has responded without a previous
call from the resident.
i
NOTICE!
When the MIYN46 Wall Transmitter is powered by an external power supply, the signal lamps
follow the state of the corresponding relay outputs.