1. SELECT BLOWER OPTION AND INSTALLATION TYPE
1.2 DUCTED INSTALLATION
The Broan Elite E60000 Series range hood includes many configurations: hoods with single or double internal blowers
(included with the hood), or hoods using external blowers. For this last category, the Broan Elite E60000 Series must be
installed with in-line blower models HLB3, HLB6, HLB9 or HLB11, or exterior blower model 331H, 332H, 335 or 336 only.
Other blowers cannot be substituted. (Blowers sold separately).
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1, 2, 3, 4, 6, 10, 12 and
up of this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7”, 8” or 10”
round ducts, use a transition (internal blowers only). Use 2” duct tape to seal duct joints.
MODEL 331H, 332H, 335 OR 336
EXTERIOR BLOWER TYPICAL DUCTWORK
MODEL HLB3, HLB6, HLB9 OR HLB11
IN-LINE BLOWER TYPICAL DUCTWORK
1.1 NON-DUCTED INSTALLATION
For a non-ducted installation, a recirculation kit ANKE60 Series (sold separately) must be installed. For maximum effectiveness,
we recommend installing this kit with a single (internal) blower hood. The kit fits hood from 30-inch width up to 48-inch
width. See installation instructions included with the non-duct kit ANKE60 Series.