13
Table 3 — Electrical Data-- 551C (cont)
VOLT AGE RANGE COMPRESSOR (each) OUTDOOR FAN ELECTRIC HEAT POWER SUPPLY * DISCONNECTSIZE
UNIT SIZE
Nominal
V --- Ph --- Hz
IFM
TYPE
CONV
OUTLET
Min Max QTY RLA LRA QTY FLA
IFM
FLA
CRHEATER
--- --- --- A00
or B00
Actual
kW†
FLA MCA
MOCP**
FLA LRA
NONE — — 9.4 15.0 9.0 60.0
006A00 5.5 7.2 12.3 15.0 11.0 60.0
NO 414 508 1 5.1 39.0 1 0.4 2.6
007A00 8.1 10.6 16.5 20.0 15.0 60.0
.
.
.
.
008A00 10.6 13.8 20.5 25.0 19.0 60.0
009A00 12.9 16.8 24.3 25.0 22.0 60.0
460 --- 3--- 60 HS
NONE — — 12.1 15.0 12.0 62.0
006A00 5.5 7.2 15.6 20.0 14.0 63.0
036 YES 414 508 1 5.1 39.0 1 0.4 2.6
007A00 8.1 10.6 19.9 20.0 18.0 63.0
(3 tons)
.
.
.
.
008A00 10.6 13.8 23.9 25.0 21.0 63.0
009A00 12.9 16.8 27.7 30.0 25.0 63.0
NO
NONE — — 7.6 10 7 35
STD
YES
518 632 1 4.2 31.0 1 0.4 1.9
NONE — — 9.7 15 9 36
NO
31.0
NONE — — 7.7 10 8 40
575 --- 3--- 60 HS
YES
518 632 1 4.2 1 0.4 2.0
NONE — — 9.8 15 10 42
Per fect
NO
31.0
NONE — — 7.7 10 8 48
Humidity
YES
518 632 1 4.2 1 0.4 2.6
NONE — — 9.8 15 10 49
551B,C