![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/8/1c/81c81057-b201-4941-8438-c96812cf0bf2/81c81057-b201-4941-8438-c96812cf0bf2-bgf0.png)
235
Value Unsigned Integer 4 1 = Master
2 = Slave
(Null to query in text)
DECAY – Decay Adjust
This command selects/reports the setting of the decay rate.
Command Form: DEVICE DECAY <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 3 (M)
Value Unsigned Integer 2 1 = Slow
2 = Medium
3 = Fast
(Null to query in text)
DEFAULT – Default The Unit
Sets the unit to factory defaults. There is no query for this command.
Command Form: DEVICE DEFAULT
No Arguments
DELAY – Delay Adjust
This command selects/reports the setting of delay time.
Command Form: DEVICE DELAY <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 5 (P)
Value Unsigned Float 2 0.00 – 250.00
(Null to query in text)
Ms
DELAYSEL – Delay Select
This command selects/reports the delay activation of an assignable processing channel.
Command Form: DEVICE DELAYSEL <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 5 (P)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
DEVICENAME – Argument Identification Label
This selects/reports the Device Argument identification label of the specific channel.
COMMAND FORM: DEVICE DEVICENAME <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 1, 2, 3, 7
(I, O, M, L)