![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/3/47/3477d3ae-f611-e084-21f1-2d8dbc593a1e/3477d3ae-f611-e084-21f1-2d8dbc593a1e-bg11.png)
17
105677
OWNER’S MANUAL
OPERATING
HEATER
Continued
TEMP
STATUS
HI
LO
MAN ON
AUTO OFF
Increases Room
Temperature
Decreases Room
Temperature
Turns Burners
On and Off
Shows Current
Operation Mode
Shows Temperature Setting
Figure 33 - Thermostat Hand-Held Remote Control Unit Selections
The Log Heater Will Automati-
cally Cycle Between Pilot and
the Heat Setting That Has Been
Selected.
Thermocouple
Pilot Burner
Figure 34 - Correct Pilot Flame Pattern
Figure 35 - Incorrect Pilot Flame Pattern
INSPECTING
BURNERS
Check pilot flame pattern and burner flame
patterns often.
PILOT FLAME PATTERN
Figure 34 shows a correct pilot flame pattern.
Figure 35 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touch-
ing the thermocouple. This will cause the
thermocouple to cool. When the thermo-
couple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown
in Figure 35
• turn heater off (see To Turn Off Gas to
Appliance, page 16)
• see Troubleshooting, pages 19 through 21
Thermocouple
Pilot Burner
Allows Burners to be
Turned On and Off with the
Hand-Held Remote Unit.
Figure 32 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for
Remote Operation
ON
OFF
REMOTE
O
F
F
P
I
L
O
T
O
N
L
O
I
H
Selector Switch in Remote Position
Control Knob in On Position
Flame Adjustment Knob
MAIN BURNER
Periodically inspect all burner flame holes
with the heater running. All slotted burner
flame holes should be open with yellow
flame present. All round burner flame holes
should be open with a small blue flame
present. Some burner flame holes may be-
come blocked by debris or rust, with no
flame present. If so, turn off heater and let
cool. Either remove blockage or replace
burner. Blocked burner flame holes will
create soot.
IMPORTANT:
This remote control
has been specially engineered to take
an air temperature sample every 5.5
minutes in the auto mode. It will not
respond immediately to the tempera-
ture setting being turned up or down.
IMPORTANT:
The hand-held remote
control unit must be near the heater.
Do not keep the hand-held remote
control unit too close to the heater.
The thermostat on the hand-held re-
mote control unit will heat up too
quickly and turn the heater off.
3. Use the STATUS button on the hand-
held remote control unit to see the
operation mode being used and the
temperature setting selected. A red
light will come on beside the opera-
tion mode being used when the sta-
tus button is pressed.
4. To turn the burners off when operat-
ing in the manual mode, press the OFF
button. If operating in the auto mode,
press the MAN button, then press the
OFF button. The pilot will remain lit.
IMPORTANT:
To turn the pilot off,
manually turn the control knob on the
heater to the OFF position.