2726
11.
D
EFAULT
A
LARM
S
ETTINGS
GAS LOW ALARM HIGH ALARM
O
2
19.5% 23.5%
LEL 10% 20%
CH
4
1.0% 1.5%
CO 35 PPM 70 PPM
H
2
S 10 PPM 20 PPM
SO
2
2.0 PM 4.0 PPM
NO
2
3.0 PPM 6.0 PPM
Cl
2
0.5 PPM 1.0 PPM
ClO
2
0.3 PPM 1.0 PPM
NOTE: Factory alarm settings may not coincide with
local regulations. Consult all appropriate local
regulations for appropriate alarm settings in
your region.
10.
S
PECIFICATIONS
CASE: Type 304 Stainless Steel
DIMENSIONS: 8.2
”L x 3.7”W x 3.2”H
(208 X 94 X 81 mm)
W
EIGHT
: 3.4 lbs (1.5 kg)
S
ENSORS
: Combustible Gases and Methane-
Catalytic
Oxygen and Toxic Gases-
Electrochemical
M
EASURING
R
ANGE
:
LEL (Combustible Gases)
0 to 100% LEL in 1% increments
CH
4
(Methane)
0 to 5% of volume in 0.1% increments
O
2
(Oxygen)
0 to 30% of volume in 0.1% increments
CO (Carbon Monoxide)
0 to 999 PPM (parts per million) in 1 PPM increments
H
2
S (Hydrogen Sulfide)
0 to 999 PPM (parts per million) in 1 PPM increments
SO
2
(Sulfur Dioxide)
0 to 99.9 PPM (parts per million) in 0.1 PPM increments
NO
2
(Nitrogen Dioxide)
0 to 99.9 PPM (parts per million) in 0.1 PPM increments
C1
2
(Chlorine)
0 to 99.9 PPM (parts per million) in 0.1 PPM increments
C1O
2
(Chlorine Dioxide)
0 to 99.9 PPM (parts per million) in 0.1 PPM increments
P
OWER
S
OURCE
: Rechargeable, replaceable nickel-cadmium battery
pack, or replaceable cell alkaline battery pack
B
ATTERY
L
IFE
: With Nicad Battery Pack - 16 hours typical
With Alkaline Battery Pack - 20 hours typical
R
EADOUT
: Alpha-Numeric Liquid Crystal Display
TEMPERATURE RANGE: -
20ºC to 50ºC (-4
ºF to 122ºF
)
With H
2
S Sensor -40ºC to 50ºC (-40
º
F to 122
º
F)
HUMIDITY RANGE: 0% to 99% RH (Non-condensing)
STORAGE TEMPERATURE: 0ºC to 20ºC (32ºF to 68ºF)
PART NUMBER DESCRIPTION (QTY)
1705-0788-PPM Combustible Sensor
1705-0129 Oxygen Sensor
1704-1898 Hydrogen Sulfide Sensor
1704-1880 Carbon Monoxide Sensor
1704-1914 Chlorine sensor
1704-4204 CLO
2
sensor
1704-1922 Nitrogen Dioxide Sensor
1704-1906 Sulfur Dioxide Sensor
1810-1386 Stainless Steel Extendible Probe - 6ft.
1810-1428 Polycarbonate Probe
1705-9494 Rechargeable Nicad Battery Pack
1705-9312 Replaceable Alkaline Battery Pack (6 C-cell)
1810-3259 Leather Carrying Case for ATX612
1810-0628 Shoulder Strap
1810-2921 Carrying Handle for ATX612
1810-1154 External Audible/Visual Alarm
1810-2146 External Vibrating Alarm
1810-2187 Cylinder Cal. Gas, H
2
S, CO, Pentane and Oxygen
1810-1576 Cylinder, Cal. Gas, Carbon Monoxide, Pentane and Oxygen
1810-2165 Cylinder, Cal. Gas, Carbon Monoxide, Methane and Oxygen
1810-1584 Cylinder, Cal. Gas, Zero Air
1810-2222 Cylinder, Cal. Gas, 5 PPM Sulfur Dioxide
1810-1758 Cylinder, Cal. Gas, 10 PPM Chlorine
1810-2219 Cylinder, Cal. Gas, 5 PPM Nitrogen Dioxide
1810-2509 Demand Flow Regulator with Pressure Gauge
12.
ATX612 O
PTIONS
& O
RDERING
I