![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/7/88/7889d6c8-d8cf-4591-976c-f6dbd6bb8fd2/7889d6c8-d8cf-4591-976c-f6dbd6bb8fd2-bg13.png)
OM-492 Page 15
4-5. Installing Exhaust Pipe
802 173-B / Ref. 189 438-A
. Point exhaust pipe in desired
direction. If unit is truck or trailer
mounted, point pipe away from
direction of travel.
Tools Needed:
1/2 in
4-6. Connecting To Weld Output Terminals
1 Positive (+) Weld Output
Terminal
2 Negative (–) Weld Output
Terminal
For MIG welding, connect work
cable to Negative (–) terminal and
wire feeder cable to Positive (+) ter-
minal.
For Stick/TIG welding, connect
work cable to Negative (–) terminal
and electrode holder cable to Posi-
tive (+) terminal.
801 941-A / Ref. 189 438-A / 802 174-E
21
POSITIVE NEGATIVE