A SERVICE OF

logo

1
Other input voltages available. Standard output voltages are 208/120, 480/277, and 600/346 volts.
For voltages not show, consult factory.
2
Panelboards furnished on "SC" models. Main output breakers furnished on "CA" models.
3
F
or e
ase in shipping and handling, unit shipped in two modules of 52 inches (132 cm) each.
4
Other input voltages available. Standard output voltages are 208/120, 380/220, 400/230 and 415/240 volts.
For voltages not shown, consult factory.
V
oltage Regulation:
F
or input voltages of ±40%,
output voltage is within +5% for any load condition
up to full load.
Overload Capacity: Supports 200% load until
circuit breaker trips, 5 to 20 minutes typical.
Output Voltage Distortion: Less than 4% total,
not additive to input distortion.
N
oise Suppression:
120dB c
ommon mode and
120dB nor
mal mode.
Effi
ciency:
89% f
or 15-20 kVA, 91% for 30 kVA,
and 93% for 50-200 kVA at full load.
In
put Power Factor:
>0.96 h
alf to full load,
reg
ardless of load power factor.
Unbalanced Loads: Output voltage is within
+5%, -2% with 100% load current unbalance.
Single Phase Protection: For loss of one input
phase, output voltages remain within 6% and
–4% up to 60%load.
Audible Noise: 55-63 dBa at 5 feet.
Monitored Parameters: Input and Output
Voltages; Output, Neutral and Ground Currents;
Output Voltage THD; Output Current THD;
K-Factor, Crest Factor; Output Power kVA, kW-
Hours; Power Factor; Percent Load; Frequency.
Alarm Conditions: Output Over- and Under-
voltages; Output Voltage THD; Output
Overload; Neutral and Ground Overcurrents;
T
ransformer Overtemperature; Frequency
Deviation; Phase Sequence Error; Phase Loss;
Five Customer Specified Alarm Conditions.
Whi
l
e e
v
e
r
y pr
ec
aution has been taken to ensure accuracy and
completeness in this literature, Liebert Corporation assumes no
r
e
s
ponsib
i
lity, and disclaims all liability for damages resulting
f
r
om u
s
e o
f this in
f
or
mation or for any errors or omissions.
© 2006 Liebert Corporation. All rights reserved throughout
the w
orld. Specifications subject to change without notice.
All n
ame
s referred to are trademarks or registered trademarks
of their respective owners.
® Li
ebert and the Liebert logo are registered trademarks
of the Liebert Corporation.
SL-20199 (R07/06) Printed in USA
Business-Critical Continuity, Emerson Network
Power and the Emerson Network Power logo
ar
e tr
a
demarks and service marks of Emerson
Electric Co. ©2006 Emerson Electric Co.
Emerson Network Power.com
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity
.
AC Power Systems
Connectivity
DC Power Systems
Embedded Computing
Embedded Power
Integrated Cabinet Solutions
Outside Plant
Power Switching & Control
Precision Cooling
Services
Site Monitoring
Surge Protection
Liebert Corporation
1050 Dearborn Drive
P.O. Box 29186
Columbus, Ohio 43229
800 877 9222 Phone (U.S. &
Canada Onl
y)
614 888 0246
Phone (Outside U.S.)
614 841 6022
FAX
Via Leonardo Da Vinci 8
Zona Industriale Tognana
35028
Piove Di Sacco (PD)
Ital
y
39 049 971
9 111 Phone
39 049 584
1 257 FAX
Eme
rson Network Power Asia Pacific
7/F., Dah Sing Financial Centre
108 G
loucester Rd, Wanchai
Hong
Kong
852 25722201 Phone
852 2802
9250 FAX
liebert.com
24 x 7 Tech Support
800 222 5877 Phone
614 841 6755 (outside U.S.)
Liebert Datawave
®
Magnetic Synthesizer
Specifications
General Specifications
60Hz
Three Input Heat Output
Phase Circuit Panel Dimensions (BTU/Hr)
Output Input Breaker Board (in) Weight @ Full Load
kVA kW Voltage
1
(Amps) Poles
2
(Wx D xH) (lbs) PF=1
15 15 208 60 42 36x34x64 1,200 6,350
480 30
600 25
20 20 208 80 42 36x34x64 1,500 8,450
480 40
600 30
30 30 208 125 42 36x34x64 1,600 10,125
480 50
600 50
50
50 208 200 84 44x32x68 2,400 12,850
480 90
600 70
75 75 208 300 84 44x32x68 2,750 19,270
480
125
600 110
100 100 208 400 120 66x36x76 3,900 25,700
480
175
600 150
125 125 208 500 120 66x36x76 4,300 32,100
480 225
600 175
150 150 208 600 120 104
3
x36x76 5,800 38,500
480 250
600 225
200 200 208 800 120 104
3
x36x76 6,500 51,400
480 350
600 300
50Hz
Three Input Heat Output
Phase Circuit Panel Dimensions (kW/Hr)
Output Input Breaker Board (cm) Weight @ Full Load
kVA kW Voltage
4
(Amps) Poles
2
(Wx D xH) (kg) PF=1
15 15 380 40 42 92x87x163 590 1.85
400 40
415 30
20 20 380 50 42 92x87x163 730 2.47
400 50
415 40
30 30 380 70 42 92x87x163 775 2.97
400
70
415
60
50 50 380 110 84 112x81x173 1,200 3.76
400 110
415 100
75 75 380 175 84 112x81x173 1,375 5.65
400
175
415 150
100 100 380 225 120 168x92x193 2,000 7.53
400
225
415 200
125
125
380 300 120 168x92x193 2,230 9.41
400 250
415 250
150 150 380 350 120 264
3
x92x193 2,950 11.29
400 350
415 300
200 200 380 450 120 264
3
x92x193 3,340 15.05
400
450
415 400