The DX9200HDDI is configured to operate in one of two ways:
• RAID 5: RAID 5 (redundant array of independent disks) provides protection in case a drive fails as the missing data can be reconstructed
from the data on the available parity drive.
• RAID 5 with Hot Spare: RAID 5 with Hot Spare adds a level of additional protection as a “hot spare drive,” which is configured and added
to the RAID array.
You use the DX9200HDDI control panel to configure the unit. Figure 12 shows the DX9200HDDI control panel. The blue keys on the control panel
are used to configure the DX9200HDDI.
Figure 12. DX9200HDDI Control Panel
Table E describes the function of the control panel keys that are described in the procedures in this section.
For information about the DX9200HDDI, refer to the DX9200HDDI Series IDE Video Storage Unit Installation/Operation manual. Figure 1 shows
the SCSI card.
Table E. DX9200HDDI Control Panel
Item Label Description
CTRL
Use the Control button to view the configuration of the storage unit, such as the memory size, firmware
version, and the brand and capacity of the hard drives.
ENC
Use the ENC button to see the operating status of the storage unit, such as the hard drive status,
temperature, power supplies, voltage, and cooling fans.
(LCD
Screen)
Used the LCD screen to view configuration menus, DX9200HDDI settings, and operational status.
!
Use the Up arrow/Quit button in conjunction with the CTRL and ENC buttons. Press to scroll through the
information on the LCD display, to move up through each menu, or to go back to the previous menu.
"
Use the Down arrow/Info button in conjunction with the CTRL and ENC buttons. Press to scroll through the
information on the LCD display or to move down through each menu, or go forward to the next menu.
!
Use the Select/C-F button to enter the option you have selected or to change the temperature display from
Celsius to Fahrenheit.