Terminal Block Connector
The terminal block connector requires the following assembly.
1. Strip the wires to 7 ~ 8 mm.
2. Insert the wires into the male part of the connector according to the operating mode you are using. See (Figure 31).
3. Use a flat-tip screwdriver to secure the wires. Tighten the screws to 6 in.-lbs.
4. Insert the plug into the receptacle on the amplifier.
5. Use a flat-tip screwdriver to secure the connector. Tighten the screws to 6 in.-lbs.
STEREO and PARALLEL INPUTS mode:
Wire as shown by loudspeaker symbols 1 and 2 on the back of the amplifier, and as shown by the solid wires in the diagram.
BRIDGE MONO mode:
Wire as shown by BRIDGE MONO loudspeaker symbol on the amplifier, and as shown by the dashed wires in (Figure 31).
Terminal Block Connector Wiring
UL IEC
Wire range - 6 mm
2
Solid wire (AWG) 28 – 10 -
Stranded wire (AWG/mm
2
) 28 – 10 -
Torque (lb.-in.) 6 -
Wire strip length 7 – 8 mm -
— Figure 31 —
— Table 3 —