INTERMITTENT DUTY ONLY!
Pump switch must be near pump and tank so operator
can hear pump running.
Make sure shut-off valve to pump and dump valve [if
equipped] are both open. Turn on momentary switch
and pump out tank.
When tank is empty, pump will get louder with a high
pitch sound. Immediately turn pump off, or damage to
impeller and housing will occur.
Do not run pump dry for more than 15 – 20 seconds.
Flush tank and pump with water after each use. This
macerator will handle normal waste, tissues, cigarettes,
fish scales, etc. It is not designed to handle large hard
objects such as large bones or fruit pits.
Periodic Maintenance and Storage: Flush with water after
each use. Check wire connections occasionally. After
periods of non-use, impeller can stick. To loosen, open rear
shaft cover and turn motor shaft clockwise with a flat tip
screwdriver. Then replace shaft cover. For extended periods
of non-use, pump impeller can be lubricated by running a
small amount of mineral oil through holding tank system.
Maintenance: Turn off all power!
Rear end cap/ motor shaft slot access:
Loosen end cap screws (17). Rotate shaft cover (16) to access
slot on motor shaft.
Pump disassembly:
Remove 3 cover screws (1). Remove cutter housing (2) and
o-ring (3). Remove hex nut (4) and cutter blades (5) & (6).
It may be necessary to hold the motor shaft steady. Insert a
screwdriver into slot on motor shaft (see slot access above),
or slip a thin wrench (9/32” [7mm]) behind blades onto flat
of motor shaft. Remove top wear plate (7), gasket (8),
impeller (9) and bottom wear plate (10). Remove impeller
housing (11) and shaft seal (12). It is not necessary to remove
slinger (13).
Pump reassembly:
Make sure slinger (13) is on shaft. Make sure shaft seal
(12) is inserted properly into rear of impeller housing (11).
Slide impeller housing (11) onto motor shaft. Seat bottom
wear plate (10) into housing. Twist impeller (9) onto shaft
and into housing with a counterclockwise motion. Install
gasket (8) and top wear plate (7). Install cutter blades (6) &
(5) with tab on bottom blade aligned with motor shaft flat.
Secure motor shaft with screwdriver or wrench (9/32”)
[7mm] and tighten hex nut (4). Position o-ring (3) and cutter
housing (2) in place, and install cover screws (1).
OPERATION\MAINTENANCE
Maintenance Tip!
Loosen stuck impeller by turning
motor shaft clockwise from rear
with a flat-tipped screwdriver.