Instructions for the installer
32
6 FINAL OPERATIONS
Having carried out the above adjustments, reassemble the appliance
following, backwards, the instructions in paragraph “
5.1 Removing the
hob”.
6.1 Regulation of minimum for natural gas
Replace the components on the burner and slide
the knobs on the gas tap pins. Light the burner
and set it at minimum position. Remove the knob
and turn the regulation screw inside or next to
the gas tap pin (depending on the model) until
you get a suitable minimum flame. Replace the
knob and check burner flame stability: (rapidly
turning the knob from maximum to minimum
position, the flame should not go out).
6.2 Regulation of minimum for LPG
To regulate the minimum for LPG, completely tighten (clockwise) the
screw inside or next to the gas tap pin (depending on the model).
The diameters of the by-passes for each burner are given in table “
5.2
Regulation for LPG”.
After having regulated the device with a gas other than the one tested,
replace the label located on the bottom enclosure with the one that
corresponds to the new gas. The label is inside the bag that contains
the nozzles.