Input connection
type
DC INPUT: Set of 2 DC bolt-down terminals. AC INPUT: hardwire
Input cord length DC INPUT: User supplies cabling. 0 gauge or larger (see manual). AC INPUT: hardwire
Recommended
Electrical Service
DC INPUT: Requires 12V DC input source capable of delivering 145A for the required duration (when used at full
continuous capacity - DC requirements increase during Over-Power and Double-Boost operation). For automotive
applications, professional hardwire
Maximum input
amps / watts
DC INPUT: Full continuous load - 145A at 12V DC. AC INPUT: 35 amps at 120V AC with full inverter and charger load
(15A max charger-only / combined input load to support charger and AC output is automatically controllable to
66%-33%-0% based on AC output l
BATTERY
Expandable battery
runtime
Runtime is expandable with any number of user supplied wet or gel type batteries
DC system voltage 12V
Battery recharge rate 19A / 75A (selectable)
LEDS ALARMS & SWITCHES
Front panel LEDs Set of 6 LEDs offer continuous status information on load percentage (6 levels reported) and battery charge level (7
levels reported). See manual for sequences.
Switches 3-position on/off/remote switch enables simple on/off power control plus auto/remote setting that enables distant on/off
control of the inverter system when used in conjunction with APSRM4 accessory (sold separately) in inverter mode. In
AC uninterruptibl
SURGE / NOISE SUPPRESSION
AC surge
suppression
450 joules AC surge suppression included
PHYSICAL
Shipping weight (lbs) 44.6
Shipping weight (kg) 20.2
Shipping
Dimensions (HWD/in)
13.5 x 15 x 21.5
Shipping
Dimensions
(HWD/cm)
34.3 x 38.1 x 54.6
Unit weight (lbs) 40.2
Unit weight (kg) 18.3
Unit Dimensions
(HWD/in)
7.25 x 8.5 x 17
Unit Dimensions
(HWD/cm)
43.8 x 21.6 x 41.3
Material of
construction
Polycarbonate
Form factors
supported
Mounting slots enable permanent placement of inverter on any horizontal surface (see manual for additional mounting
information)
Cooling method Multi-speed fan
Style Heavy-duty with built-in battery charger
ENVIRONMENTAL
Relative Humidity 0-95% non-condensing
LINE / BATTERY TRANSFER
Transfer time from
line power to battery
mode
16.6 milliseconds (typical - compatible with many computers - verify transfer time compatibility of loads for UPS
applications)
Low voltage transfer
to battery power
In AC "auto" mode, inverter/charger switches to battery mode as line voltage drops to 75V (user adjustable to 85, 95,
105V - see manual)