![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/a0/2a0c5960-ec0d-49ed-afa2-4b360995fabd/2a0c5960-ec0d-49ed-afa2-4b360995fabd-bg5.png)
— 5 —
Fig. 1
Fryers Mounted on Optional Casters
Fryers mounted on casters must use a flexible
connector (NOT SUPPLIED BY VULCAN) that
complies with the Standard for Connectors of
Movable Gas Appliances, ANSI-Z21.69 • CSA6.16
and a quick-disconnect device that complies with
the Standard for Quick-Disconnect Devices for Use
With Gas Fuel, ANSI-Z21 • CSA 6.9.
In addition, adequate means must be provided to
limit the movement of the appliance without
depending on the connector and the quick-
disconnect device or its associated piping to limit
the appliance movement. Attach the restraining
device to the rear of the fryer as shown in Fig. 1.
If it is necessary to disconnect the restraint, turn off the gas supply before disconnection. Reconnect
the restraint before turning the gas supply on and returning the fryer to its installation position.
Instructions for installing casters to the fryer are included with the casters.
LEVELING THE FRYER
Stand Alone Installations
Once gas connections have been made, place a spirit level on top of the fryer. Adjust the legs to
ensure that the fryer is level front-to-back and side-to-side in the final installed position.
Battery Installations
When the fryer is part of a battery lineup, line the fryer up front-to-back and side-to-side with
adjacent battery equipment. Equipment front tops and manifold pipes must be aligned with adjacent
equipment. Once the fryer is in its exact location in the battery lineup, place a spirit level on top of
the fryer. Adjust the legs to ensure that the fryer is level front-to-back and side-to-side in the final
installed position.