FILTER PUMP / MOTOR
ASSEMBLY INSTRUCTIONS
CAUTION: New style motor is a dual voltage rated unit, and must be field
wired to match the electrical service supply voltage. Motor may be shipped
wired for either 230V or 125V. Verify the supply voltage and the motor voltage
configuration. If necessary, rewire motor, at the terminal block in the end of the
motor, per the table shown below. Also, see diagram on motor.
WARNING: Failure to correctly wire the motor will result in permanent
damage to the pump motor.
125V 230V
1 (LINE) YELLOW / BLACK 1(LINE) YELLOW / BLACK
2 BLUE 2 BLUE
BLUE BLUE
3 (UNUSED) 3 BROWN
4 BLACK 4 BLACK
5 BROWN 5 WHITE
ORANGE ORANGE
6 (LINE) WHITE 6 (LINE) YELLOW