The illustrations below provide installation
specifications for Model ICBCT36E.
For ease of installation, 991 mm cabinets
are recommended for installation of Model
ICBCT36E.
A Wolf 762 mm or 914 mm built-in single oven
may be installed below Model ICBCT36E. For
this installation, unless you are using cabinets
deeper than 610 mm, it is recommended that
the electrical supply be placed in the base
cabinet to the right of the oven.
Refer to installation instructions provided with
the built-in oven for additional specifications.
If Model ICBCT36E is installed above cabinets,
the electrical placement is not critical. A
grounded electrical box should be located
within 1.2 m of the right rear of the cooktop.
IMPORTANT NOTE:
Do not block the cooling
fan located at the bottom of the cooktop.
*Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 457 mm above countertop. **Minimum clearance from
rear edge of cooktop cut-out to combustible materials up to 457 mm above countertop.
MODEL ICBCT36E
Overall Width 914 mm
Overall Height 96 mm
Overall Depth 533 mm
Minimum Cabinet Depth 578 mm
Minimum Height Clearance*
102 mm
Cut-Out Width 873 mm
Cut-Out Depth 489 mm
INSTALLATION SPECIFICATIONS – MODEL ICBCT36E
*Minimum 146 mm clearance is required
between countertop and any combustible
surface directly below the cooktop.
For detailed terminal block dimensions,
refer to the illustration on page 7.
Dimensions may vary to
±