3M SC 250/900m TV Cables User Manual


 
8 78-0013-1746-6-E
3.11 Lay the fiber in the track running through the center of the fiber holder. Use the “TIGHT BUFFER” or “SEMI-
TIGHT BUFFER” slits as appropriate. Reference section 3.3 to determine which fiber type.
Tight buffer Semi-tight buffer
3.12 Move shuttle forward. Leave at least one finger width
of buffer extending beyond the nozzle. Hold the
buffer at both ends of the fiber holder, pull the fiber
straight, and set the fiber in the center tracks. Close
the back lid, but don't latch it. Close the front and
middle lid.
3.13 Snap the front and middle lids shut. Push the shuttle
forward again until it stops.