Aphex Systems 1788a Universal Remote User Manual


 
Page 16 Page 17
R/C Manual
2. USING MIDI
2.5 REFERENCE DATA
2.5.1 Parametric Codes & Values
1788A Parametric MIDI Commands
Command Control Value Range
00h Input Gain 1Ah to 41h (26 to 65)
01h Main Max Out 00h to 1Bh (0 to 27)
02h Aux Max Out 00h to 1Bh (0 to 27)
03h Phantom Power 00h = OFF, 01h = ON
04h Low Cut Filter 00h = OFF, 01h = ON
05h Limiter (MicLim) 00h = OFF, 01h = ON
06h Polarity Reverse 00h = OFF, 01h = ON
07h Mute 00h = OFF, 01h = ON
08h Pad 00h = OFF, 01h = ON
0Ah Test Tone -20dB 00h = OFF, 01h = ON
0Bh Test Tone 0dB 00h = OFF, 01h = ON
17h Test Tone (alternative method) 00h = OFF, 01h = -20dB, 02h = 0dB
20h Request Parameter SysEx Dump 01h (required)
56h Request Extended SysEx Dump 00h (any value placeholder byte)
F0 00 00 38 xx xx xx xx xx
F7
SysEx Start
MIDI Channel
MIDI Device
xx
Net Number
Command
Mic Channel
Value
xx xx xx
Command
Mic Channel
Value
xx xx xx
Command
Mic Channel
Value
SysEx End
Put 1 to 64 3-byte Commands Here
Aphex MIDI I.D.
System Exclusive (SysEx) Parametric Control String