Audiovox VOH560PKG VCR User Manual


 
Troubleshooting:
Symptom:
No power at Video Monitor
Power but no video or sound
Picture, but no sound
No Infrared remote functions
for VCP (or other compo-
nents)
Remedy:
-Verify +12 VDC on Red wire at 2 pin Power Harness behind video moni-
tor. Verify ground connection with continuity test from known good ground
to black wire at 2 pin Power Harness
-Verify that the correct source is selected (i.e.: 1, 2 or 3). Verify that the
source is on and playing a known good media (such as a videotape). Verify
connections at both ends of the source component harness.
-Push and hold the volume up button until sound is heard over headphones.
If problem is limited to the dash radio, verify radio is tuned to the correct
channel, and that power to the wired RF modulator is on. (Refer to instruc-
tions with modulator kit). Otherwise, verify all connections per the wiring
diagram on page 6.
-Check batteries in the hand held remote (not included with this kit). Verify
that the IR LED ( page 6 Wiring Diagram) is property attached to the sen-
sor window of the VCP (or other component).
Negative Switched Dome lighting
To 12 pin
connector
on Monitor
To
constant
+12vdc
To
constant
+12vdc
Factory Door ajar
switch or Body
Control computer
Factory Dome light circuit
-8-
Red / black - Lamp on
Black / red - Lamp common
Purple / brown - Lamp Auto