42
PGXG-61B/PGWX-61B/PGWU-61B - - 2015/04/01
6. Maintenance & Service
Turn the projector off and unplug the power cord. 1.
Allow the projector to cool down for at least 30 minutes.2.
Unscrew the sixs crews on the cover. 3.
1
Lift up and remove the cover.4.
Unscrew the three screws on the lamp module. 5.
2
Lift up the lamp handle and remove the lamp module slowly and carefully. 6.
3
To replace the lamp module, reverse the previous steps.7.
Turn on the projector and use “Lamp Hour Reset” after the lamp module is replaced.8.
6.1 Replacing the Lamp
Procedure:
1
2
3
Warning: This procedure may only be performed by qualied technical service personnel.
The projector automatically detects the lamp life. When the lamp life is nearing the end of use, you can see the lamp
REPLACE information in “Lamp INFO” of OSD lite menu. Make sure the projector has been cooled down for at least 30
minutes before changing the lamp.
Lamp life:
6. MAINTENANCE & SERVICE
Overview
Replacing the Lamp y
Replacing the Air Filter y
Replacing the Lens y