Black Box IC107C-R3 Cable Box User Manual


 
13
CHAPTER 5: Operation
5.2 RS-422/485 Circuitry
The RS-422/485 side of the Converter is made up of the driver, receiver, and line-
termination networks. As described in Chapter 3, you can use switch S2 to either
connect the receiver’s termination network to the line (terminate the RS-422/485
port) or leave it unconnected (unterminated).
Having the line terminated will reduce distortion and improve the overall signal
quality in most applications. For point-to-point systems where only two devices are
connected to the line, each device should have the termination network connected
to the line. In multipoint applications, only the two devices at the extreme ends of
the line should have the termination network connected to the line. If any of the
other converters were configured as “terminated,” the amount of signal distortion
would increase and probably cause errors in the data being transmitted. For more
on the RS-422/485 connector pinning, see the Appendix.