6.4 Event
Use the Event menu to specify the desired behavior for an Input, detected Motion, or System
failures; also define how alarms are acknowledged.
6.4.1 Input
Figure 6.12 Event - Input
Inputs are always active on the unit.
Note:
For 16-channel units, use the ch09 to ch16 or ch01 to ch08 button to display the required
input.
Input Type
The Event behavior can be configured independently for each channel.
– N.O. - Normally Open causes an alarm to trigger only when the circuit closes
– N.C. - Normally Closed causes an alarm to trigger only when the circuit is opened
Camera
Set the camera between 1 and 8/16, which is set to an alarm based on the input.
Relay output
Select the relay to trigger in response to the input.
PTZ
– For the camera associated with the input, a PTZ preset can be sent to the camera to
move to a specified pre-position.
– Enter a pre-position number from 1-255 for each of the PTZ cameras that should be
moved.