Denon AVR-4802R TV Cables User Manual


 
- 9 -
EVENT(or RESPONSE) and PARAMETER list
EVENT PARAMETER function example *RES.
PW ON POWER ON/STANDBY change PWON<CR>
STANDBY PWSTANDBY<CR>
MV ** MASTER VOLUME change , **:00 to 98 by ASCII MV80<CR>
98 = +18dB(MAX)
80 = 0dB
10 = -70dB
99 = ---dB(MIN)
CV FL ** CHANNEL VOLUME change , **:38 to 62 by ASCII CVFL 50<CR>
FR ** 62 = +12dB(MAX) CVFR 50<CR>
C ** 50 = 0dB CVC 50<CR>
SW ** 38 = -12dB(MIN) CVSW 50<CR>
SL ** 00 = OFF (define ONLY SWch in DIRECT mode.) CVSL 50<CR>
SR ** CVSR 50<CR>
SBL ** (at SBch 2SP) CVSBL 50<CR>
SBR ** (at SBch 2SP) CVSBR 50<CR>
SB ** (at SBch 1SP) CVSB 50<CR>
MU ON OUTPUT MUTE ON/OFF change MUON<CR>
OFF MUOFF<CR>
SI PHONO INPUT source change SIPHONO<CR>
CD SICD<CR>
TUNER SITUNER<CR>
DVD SIDVD<CR>
VDP SIVDP<CR>
TV SITV<CR>
DBS/SAT SIDBS/SAT<CR>
VCR-1 SIVCR-1<CR>
VCR-2 SIVCR-2<CR>
VCR-3 SIVCR-3<CR>
V.AUX SIV.AUX<CR>
CDR/TAPE1 ---means CDR/TAPE function at AVR-4802R SICDR/TAPE1<CR>
MD/TAPE2 ---Invalid at AVR-4802R SIMD/TAPE2<CR>
*RES. : NOT returns '*' parameters as RESPONSE.