DolbyRemote Installation and Operation Dolby Digital Parameters
4-14
does not guarantee that a valid test tone will be produced at the output of the DP567
or DP569. Dolby Digital encoding must also be active, which requires that the
selected clock source be valid. The selection of a Test Tone mode automatically
overrides the input format settings. All other settings remain active.
4.5.5 Stream Number
Input
Input shows the input stream number for a pre-encoded signal present at the
reference input.
Output
Output defines the stream number for the Dolby Digital output of the encoding
process. The default is zero. If multiplex mode is currently active, the selected stream
number cannot be identical to that of a stream currently being received.
4.6 Reference Input
Figure 4-7 Reference Input
4.6.1 Reference Input
Lock Status
Lock Status shows whether the reference input has been detected and locked.
Sample Rate
Sample Rate shows the sample rate of the reference input.
Integrity