Eiki LC-XT1 CRT Television User Manual


 
LC-XT1
.
On start
When this function is “On” the projector is automatically turned on just by switching the MAIN ON / OFF SWITCH on. NOTE: Be sure
to turn the projector off properly (refer to the section “TURNING OFF THE PROJECTOR” on page 23). If
the projector is turned off in the wrong steps, the On Start function does not operate properly.
Lamp Mode
This Projector is equipped with 4 Projection Lamps and the number of using lamps can be switched to 4 lamps or 2 lamps.
Using 2 lamps maintains the life of the Projection Lamps.
To change over Lamp Mode
1. Press the MENU button the ON-SCREEN MENU will appear. Press the POINT LEFT/RIGHT buttons to select SETTING and
press the SELECT button. Another dialog box SETTING MENU will appear.
2. Press the POINT DOWN button and move a red-arrow icon to Lamp Mode. Set “4 lamps mode” or “2 lamps mode” by pressing
the SELECT button. When Lamp Mode is set from “4 lamps mode” to “2 lamps mode,” the image becomes little darker. When
Lamp Mode is set from “2 lamps mode” to “4 lamps mode,” the image become brighter gradually.
NOTE : After changing Lamp Mode, it cannot be switched again for 90 seconds.
Remote control
This projector has two different remote transmit codes; the factory-set normal code (Mode 1) and the secondary code
(Mode 2). This switching function prevents the remote control operation mixture (jam) when operating several projectors
or video equipment together.
When operating the projector in “Mode 2” both projector and Remote Control must be switched to “Mode 2”.
To change the code of the projector
Set the Remote control in the SETTING menu to “Mode 2”.
To change the code of the Remote Control
Press both the MENU and the NORMAL buttons on the Remote Control together for over 10 seconds.
After changing the code, make sure the Remote Control operates properly.
To return to the normal code (Mode 1), operate both projector and Remote Control in the ways above again.
NOTE: When the ALL-OFF switch on the Remote Control Unit is turned to “ALL-OFF” the remote transmit code automatically
returns to the normal code (Mode 1).