47
DTR-60XX
Setup menu (continued)
Event – Alarm-In
On the “Alarm-In” menu the alarm inputs and responses to events are congured.
Setup Menu...
Event Alarm-In Settings
Term Symbol Meaning
No. Enables the alarm inputs
Title Name of alarm input
Type
Contact method of alarm input:
NO Normally Open
NC Normally Closed
Setup Menu...
Event Alarm-In Actions 1
Term Symbol Meaning
No. Number of alarm input
Record
Assignment of cameras to record in event of alarm
These cameras must be in “Event” or “Time and Event” mode within
the time slot:
Setup Menu... > Record > Schedule
Alarm-Out
Assign and enable
alarm outputs
internal beep by DVR
These alarm outputs and the internal beep must be enabled within
the time slot:
Setup Menu... > Devices > Alarm-Out > Schedule
●
●
Notify
Assign and enable notications:
Mail
Modem
LAN 1 to LAN 5
Alert Window
The selected function must be enabled:
Setup Menu... > Network > Notication