EverFocus EDSR-900 DVR User Manual


 
MENU
29
6.16 PTZ SETTING MENU
The EDSR600/900/1600 Recorder from FW 1.09 provides telemetry control over network.
Local device telemetry control at the EDSR recorder is not possible. Telemetry bus may be
connected to RS-232 or RS-485.
In the PTZ SETTING MENU, we define
PTZ ENABLE: ON activates telemetry function / OFF disable telemetry function.
PTZ - Port: Selection of active telemetry port, RS232 or RS485.
ATTENTION: If the EDSR is remote controlled by RS-485 keyboard, and
telemetry must be connected to the RS232 - port (with interface converter)
PROTOCOL: Supported protocols: PELCO-D, PELCO-P, EVERFOCUS* und VPROTECT*
(* reserved for future us, currently not supported)
BAUD RATE: There are 6 telemetry transmission rates, selectable 1200, 2400, 4800, 9600,
19200, 38400 baud rate.
PTZ-ADRESS: Telemetry receiver / Dome camera address assignment to the video inputs
PTZ SETTING MENU
PTZ ENABLE: OFF
PTZ Port: RS485
PROTOCOL: PELCO-D
BAUD RATE: 9600
PTZ ADDRESS:
CH1: 001 CH9: 009
CH2: 002 CH10: 010
CH3: 003 CH11: 011
CH4: 004 CH12: 012
CH5: 005 CH13: 013
CH6: 006 CH14: 014
CH7: 007 CH15: 015
CH8: 008 CH16: 016
Turn the JOG dial clockwise or counter-clockwise to select the options.
Press MENU key to return to Main Menu, press again to leave Set up Menu.
MENU
Press ENTER key to confirm the option and move to next column.
ENTER