3
3
Troubleshooting:
PROBLEM CAUSE
CORRECTIVE
ACTION
Does not
operate,
display does
not light.
No power to
Yellow wire,
No power to
Red
Check power
connection with
Multi-meter. Check
fuse for continuity
with Multi-meter.
Inline fuse
blown
Replace fuse.
No power to
unit
Inline fuse
blown
Check and/or
replace fuse.
No Audio to
speakers
Speaker
harness not
connected
Check speaker
wires, connect
harness.
Blows fuses
Power wire
shorting to
ground
Make sure wire is
not pinched.
Speaker
wires shorting
to ground
Make sure wire is
not pinched.
Incorrect
fuse/ rating
too small
Replace with
proper fuse.
CD/DVD skips
Mounting
angle is too
great or not
secure.
Check proper
mounting angle
and/or mounting
strap for secure
mounting.
Dirty laser.
Use CD/DVD
cleaning kit.
ERROR
DISPLAY
CDP and CDC
ERR1 appears
on display
Mechanism
Error
Press Reset button.
ERR6 appears
on display
Sled Error Press Reset button.
CDP ONLY
ERR2 appears
on display
Servo Error Press Reset button.
ERR7 appears
on display
TOC reading
error
Check disc - disc
may be dirty or
upside down. If not
press the reset
button.
CDC ONLY
ERR2 appears
on display
TOC reading
error
Check disc - disc
may be dirty or
upside down. If not
press the reset
button.
ERR3 appears
on display
Temperature
error
Press Reset button.
ERR7 appears
on display
Disc and
Servo error
Press Reset button.