3-4 Editing system examples
3 CONNECTIONS
The BR-DV600U can be used as a feeder for different video formats.
5
Simplified digital cut editing system
Using an editing remote controller with JVC bus specifications such as the RM-G800, digital cut editing is possible with
another MiniDV VCR. When the BR-DV600U is used as a recorder, the following editing operations cannot be performed.
• Preview
• Insert editing
• EE function (auto EE function)
As the phase sync function does not work, the editing accuracy is ±5 frames.
RM-G800
DV (IEEE1394)
Remote control
Notes:
• When used in an editing system with the RM-G800,
the BR-DV600’s preroll operation is comparatively
slow. This is normal and is not a malfunction.
• When editing, the input signal (picture from the
playback VCR) can be monitored. The playback
picture of the recorder VCR just before the edit-in
point cannot be checked.
• This unit cannot be used for CTL editing. Use for
the time code editing.
• During remote control operation, be sure to turn the
jog dial slowly. Otherwise, the VCR may not be able
to keep up with the operation.
• When this unit is operated with the remote control
unit, audio cannot be checked if it is played back at
a speed of less than 1x.
• If editing is started in the Pause mode (still) at the
preroll point, editing accuracy may be degraded.
• Use the RM-G800 with the out-point return function
OFF. Otherwise, it takes longer to stop editing.
• Use the RM-G800 with the Auto EE mode OFF.
Otherwise, the IEEE 1394
“EE inh” error indication is
shown.
For servicing
See the service manual page 1-20 “1.11 EDITING SYSTEM USING THE BR-DV600”.
→
15
3 CONNECTIONS
3-4 Editing system examples
5
Mixed S-VHS/VHS system
This is an editing system which uses the BR-DV600U as a feeder/player with an RS-422A serial remote controller such as
the RM-G820. In this case, the BR-DV600U cannot be used as a recorder VCR.
The S-VHS/VHS VCR can be replaced with a D-9/Betacam VCR.
The following editing operations are not available.
• Variable search
• Slow-motion editing
• CTL editing
RM-G820
Video signal
Remote control
Audio signal
Notes:
• Even during the time code editing, the editing
accuracy of 0 frame cannot be obtained. Set the
remote control’s sync grade to ±1 frame.
• During remote control operation, be sure to turn the
jog dial slowly. Otherwise, the VCR may not be able
to keep up with the operation.
• When this unit is operated with the remote control
unit, audio cannot be checked if it is played back at
a speed of less than 1x.