22
363 CONTROLLER SELECT
Details: Selects the setting according to the type of
remote control unit connected via the
RS-422A interface.
Setting:
qTYPE 1 (00):For the RM-G820.
TYPE 2 (01):For a non-linear editing system.
TYPE 3 (02):For BR-S822 swap and BR-D92
swap.
TYPE 4 (03):Unused.
:
TYPE 8 (07)
396 BATTERY SELECT
Details: When using DC power, set this switch
according to the DC power supply and
battery type.
Setting:
q12 V (00): Select this setting to use a DC power
supply (AA-G10) or DC 12 V flat shape
type battery.
13.2 V (01): Select this setting to use Anton Bauer
Inc.’s Trimpack 13, ProPac 13.
14.4 V (02): Select this setting to use Anton Bauer
Inc.’s Trimpack 14, ProPac 14 and IDX
Corporation's NP-L46.
397 FAN STOP SHUTDOWN
Details: Sets whether or not VCR operation continues
if the fan motor stops.
Setting:
qENABLE (00): The power turns off about 1 minute
after the fan motor stops.
DISABLE (01): The VCR continues operation even
after the fan motor stops.
When the fan motor stops, press
the [OPERATE] button as soon as
possible to turn the VCR’s power
off. If not, a malfunction may occur
due to overheating.
399 REMOTE FF/REW MODE
Contents:Selects the operation when FF/REW
command is received by a REMOTE
connector (with the exception of the
serial remote connector) during playback.
Setting:
qFF/REW(00): The mode becomes the FF/REW
mode when the command is
received. Normally, use this setting.
SEARCH (01): The mode becomes the SEARCH
mode when the command is
received. Use this setting when
CUE operation fails to work
normally when the
“FF/REW”
setting is selected.
413 TCG SOURCE
Details: Selects the time code to be recorded.
Setting:
qINTERNAL (0): Uses the time code from the built-in
generator.
EXTERNAL (1): Uses the time code from the
timecode generator connected to
the [TIME CODE IN] connector.
q: Factory setting
(00): The number in the bracket shows the set value
on thecounter display.
312 AUTO REW
Details: Selects whether or not the tape is rewound
automatically at tape end during recording or
playback.
Setting:
qOFF (00): The tape is not rewound automatically.
ON (01): The tape is rewound automatically.
Repeat playback is available when No.
311 <AUTO PLAY> menu switch is set to
“PLAY”.
353 EDIT ADJUST
Details: When this unit is used with an editing
controller and the edit-in point is shifted, this
corrects the play start timing.
Switch setting differs depending on the
configuration of the editing system. For
details, refer to
“Edit adjust setting
” on page 1
7.
Setting:
q0F: No compensation.
1F: The playback start point is delayed by 1 frame.
2F: The playback start point is delayed by 2 frames.
3F: The playback start point is delayed by 3 frames
to the factory set timing.
4F: The playback start point is delayed by 4 frames.
5F: The playback start point is delayed by 5 frames.
6F: The playback start point is delayed by 6 frames.
7F: The playback start point is delayed by 7 frames.
360 AUTO REW AT TIMER
Details: Selects whether or not the tape is
automatically rewound when the VCR
power is switched ON in the Timer Play or
Recording Standby mode.
Setting:
qOFF (00): Playback or recording starts
immediately. The tape is not rewound.
ON (01): Playback or recording starts after the
tape is rewound to the beginning.
362 BACK UP REC TIMING
Details: For backup recording, set this according to
the length of the recording on the tape in the
source VCR.
For details, refer to
“Backup recording
function” on page 36.
Setting:
qOFF (00) :Backup recording is not performed.
25MIN (01) : When the length of the recording on
the tape in the source VCR. is 30
minutes.
55MIN (02) : When the length of the recording on
the tape in the source VCR. is 60
minutes.
75MIN (03) : When the length of the recording on
the tape in the source VCR. is 80
minutes.
4 MENU SWITCHES
23
4 MENU SWITCHES
q: Factory setting
(00): The number in the bracket shows the set value
on thecounter display.
414 TCG SELECT
Details: Selects the time code generator mode.
Setting:
qPRESET (00): Engages the Preset mode.
REGEN (01): Engages the Regen mode.
415 TCG MODE
Details: Selects the time code generator Run mode.
Setting:
FREE RUN (00):Engages the Free Run mode.
qREC RUN (01): Engages the Rec Run mode.
416 NON DROP/DROP (U MDEL)
Details: Selects the time code generator Drop Frame
mode.
Setting:
qDROP (00): Engages the Drop Frame mode.
NON DROP (01): Engages the Non-Drop Frame
mode.
460 TC DUPLICATE
Details: Selects the time code when the [DV IN]
connector is used during recording.
Setting:
qOFF (0): Records the time code from the built-in or
external time code generator.
ON (1): Records the time code input to the [DV IN]
connector.
500 ON SCREEN
Details: Selects whether or not the on-screen display
is shown on the monitor.
Setting:
OFF (00): The display is not shown.
qON (01): The display is shown.
501 CHARACTER H.POSITION
Details: Moves the display position of the tape
counter on screen, etc. horizontally.
Setting:
q The display position can be moved in 9
steps from 0 to 8. The factory setting is
“0” (the display position at the far right).
* The tape remaining time indication
position cannot be changed.
502 CHARACTER V.POSITION
Details: Moves the display position of the tape
counter on screen, etc. vertically.
Setting:
The display position can be moved in
q 12 steps from 0 to 11. When the
No. 504<INFORMATION SELECT>
menu switch is set to “MODE + TIME>,
setting to “0” is not possible.
* The tape remaining time indication
position on screen can be changed up
and down with this switch.
0 (00)
:
8 (08)
0 (00)
1 (01)
:
11 (11)
504 INFORMATION SELECT
Details: Selects which information is displayed on the
on-screen display.
Setting:
TIME (00): Time data is displayed
qMODE+TIME (01):Time data and tape running
mode are displayed.
505 REMAIN ENABLE
Details: Selects whether or not the tape remaining
time is shown on the on-screen display.
Setting:
qOFF (00): Remaining time is not shown.
ON (01): Remaining time is shown.
514 TIME DISPLAY SELECT
Details: Selects the type of time data displayed.
Setting:
DATE (00): Shows the date.
CLOCK (01): Shows the time.
DATE+CLOCK (02):Shows the date and time.
qTC (03): Shows the time code data.
516 DISPLAY SELECT
Details: Selects the type of data displayed on the tape
counter in the LCD display.
Setting:
qTC (00): Shows the time code data.
CLOCK (01):Shows the date and time. You can
switch between date and time with the
[COUNTER] switch.