LEVEL DIAGRAM (TX SECTION)
MIC
IC535 IC529
IC524
IC523
IC515
IC516
IC518
DSP 6 1
1
IC6
Q54
XF9
Q711
L109 L108
L105
D84
D82
Q49
Q48
L102
CN11
12TIF
CN49
TIF
Q46
Q47
Q44
Q45
L98
L91
Q46
Q47
L2
L5 L9
L10
Q1
Q2
XF3 D54
–20.6dBm –5dBm –16dBm –5dBm
–17dBm –7dBm –13dBm
–20dBm –15dBm
+2.0dBm
2dBm
0.3W 6W 60W0dBm
L95
L96
Q43 Q3 Q5 Q6
Q7
Q8
Q101
Q102
CN14
HFTX
CN1
HFTX
CN2
14TX
Q901
L14
L16
CN4
HFPO
CN803
14PO
CN4
HFPIN
HF/50MHz
ANT
50W
HF/
50MHz
VHF
14PIN
VHF
ANT
100W
CN18
TIF
Q17 Q26
Q18
Q20
15
IC3
CN3
43TX
CN901
43TX
CN4
14TX
Q304
Q3
480mVp-p370mVp-p750mVp-p
600mVp-p
210mVp-p 0.5mW 4mW 63mW (13W)
400mVp-p1.2Vp-p70mVp-p
Q903 Q905
UHF
ANT
50W
L320
L321
XF2
L7,8
D1
MIX
L12
14
IC1
Q5 Q6
14
IC3
280mVp-p
440mVp-p 450mVp-p
140mVp-p
45mVp-p
5mV 112mVp-p 81mVp-p
100mVp-p 100mVp-p 19mVp-p
240mVp-p
41mVp-p
130mVp-p
30mVp-p
78mVp-p
50mVp-p 91mVp-p
430mVp-p
35Vp-p
36Vp-p 250Vp-p
230Vp-p
CONTROL UNIT (X53-391)
AF 1kHz TIF 12kHz
TX-RX 1 UNIT (X57-605 A/10)
10.595MHz 68.985MHz 14.2MHz
FINAL UNIT (X45-384 A/2)
FILTER UNIT
(X51-318)
10.595MHz
41.795MHz 144MHz or 438MHz
TX-RX 2 UNIT (X57-606 A/11)
FINAL UNIT (X45-384 B/2)
12ANT
10W
CN5
12TIF
1270.2MHz
135.395MHz10.595MHz
TX-RX 3 UNIT (X57-607)
HPF
Measurement condition (TX-RX 1 unit)
Frequency : 14.2MHz
MIC input : 1kHz/5mV
Output power : 100W (HF, VHF), 50W (UHF)
MIC level : ALC zone maximum
Audio frequency section is measured by the AF voltmeter or oscilloscope.
Radio frequency section is measured by the RF voltmeter or oscilloscope.
The value in parentheses ( ) for the fi nal unit (X45-384 B/2) is a reference value.
Measurement condition (TX-RX 2 unit)
Frequency : 144MHz (VHF), 438MHz (UHF)
MIC input : 1kHz/5mV
Output power : 100W (VHF), 50W (UHF)
MIC level : ALC zone maximum
Measure the power using the RF voltmeter.
Measurement condition (TX-RX 3 unit)
Frequency : 1270MHz
MIC input : 1kHz/5mV
Output power : 10W
MIC level : ALC zone maximum
Measure the voltage or power using the oscilscope or spectrum analyzer.