LG Electronics 32LD350-UA Flat Panel Television User Manual


 
- 13 -
LGE Internal Use OnlyCopyright LG Electronics. Inc. All right reserved.
Only for training and service purposes
2) Adjustment Map
Applied Model : 19LD350-UB, 22LD350-UB, 26LD350-UB,
32LD350-UB
(5) Adj. method
Auto adj. method
1) Set TV in adj. mode using POWER ON key
2) Zero calibrate probe then place it on the center of the
Display
3) Connect Cable(RS-232C)
4) Select mode in adj. Program and begin adj.
5) When adj. is complete (OK Sing), check adj. status pre
mode (Warm, Medium, Cool)
6) Remove probe and RS-232C cable to complete adj.
* W/B Adj. must begin as start command wb 00 00 , and
finish as end command wb 00 ff, and Adj. offset if
need
Manual adj. method
1) Set TV in Adj. mode using POWER ON
2) Zero Calibrate the probe of Color Analyzer, then place
it on the center of LCD module within 10cm of the
surface..
3) Press ADJ key -> EZ adjust using adj. R/C > 6. White-
Balance then press the cursor to the right (KEY
G).
(When KEY(
G) is pressed 216 Gray internal pattern
will be displayed)
4) One of R Gain / G Gain / B Gain should be fixed at
192, and the rest will be lowered to meet the desired
value.
5) Adj. is performed in COOL, MEDIUM, WARM 3 modes
of color temperature.
- If internal pattern is not available, use RF input. In EZ
Adj. menu 6.White Balance, you can select one of 2
Test-pattern: ON, OFF. Default is inner(ON). By
selecting OFF, you can adjust using RF signal in 216
Gray pattern.
* Adj. condition and cautionary items
1) Lighting condition in surrounding area
Surrounding lighting should be lower 10 lux. Try to
isolate adj. area into dark surrounding.
2) Probe location
- LCD: Color Analyzer (CA-210) probe should be
within 10cm and perpendicular of the module
surface (80°~ 100°)
3) Aging time
- After Aging Start, Keep the Power ON status during 5
Minutes.
- In case of LCD, Back-light on should be checked
using no signal or Full-white pattern.
(6) Reference (White Balance Adj. coordinate and color
temperature)
Luminance: 216 Gray
Standard color coordinate and temperature using CS-
1000 (over 26 inch)
26/32LD350-UB
19/22LD350-UB (Small size panel have different color
coordinate)
Standard color coordinate and temperature using CA-
210(CH 9)
26/32LD350-UB
19/22LD350-UB (Small size panel have different color
coordinate)
ITEM Command Data Range Default
(Hex.) (Decimal)
Cmd 1 Cmd 2 Min Max
Cool R-Gain j g 00 C0
G-Gain j h 00 C0
B-Gain j i 00 C0
R-Cut
G-Cut
B-Cut
Medium R-Gain j a 00 C0
G-Gain j b 00 C0
B-Gain j c 00 C0
R-Cut
G-Cut
B-Cut
Warm R-Gain j d 00 C0
G-Gain j e 00 C0
B-Gain j f 00 C0
R-Cut
G-Cut
Mode Color Coordination Temp UV
xy
COOL 0.269 0.273 13000K 0.0000
MEDIUM 0.285 0.293 9300K 0.0000
WARM 0.313 0.329 6500K 0.0000
Mode Color Coordination Temp UV
xy
COOL 0.285 0.293 9300K 0.0000
MEDIUM 0.295 0.305 8000K 0.0000
WARM 0.313 0.329 6500K 0.0000
Mode Color Coordination Temp UV
xy
COOL 0.269±0.002 0.273±0.002 13000K 0.0000
MEDIUM 0.285±0.002 0.293±0.002 9300K 0.0000
WARM 0.313+0.002 0.329±0.002 6500K 0.0000
Mode Color Coordination Temp UV
xy
COOL 0.285±0.002 0.293±0.002 9300K 0.0000
MEDIUM 0.295±0.002 0.305±0.002 8000K 0.0000
WARM 0.313+0.002 0.329±0.002 6500K 0.0000