LG Electronics 32LQ630H CRT Television User Manual


 
25
206-4207
079 - UPN MSB-1 (UPN Most Signicant Byte-1)
User programmable number, most signicant byte-1 readable by
MPI command. Note: Not linked to serial number.
080 - UPN MSB-2 (UPN Most Signicant Byte-2)
User programmable number, most signicant byte-2 readable by
MPI command. Note: Not linked to serial number.
081 - UPN LSB (UPN Least Signicant Byte)
User programmable number, least signicant byte readable by
MPI command. Note: Not linked to serial number.
082 - CHKSM ERROR (Checksum Error)
Enforces rigid MPI checksum validation. Set to 1 for validation.
Set to 0 to disable (does not check checksum on MPI async port).
SPI is always checked.
083 - HANDSHK TIME (Handshake Time)
Adds an additional delay to the handshake time which is 64 msec,
thus relaxing MPI timing requirements to be compatible with PC-
based Windows controlled systems. Range is 0 - 5.
(Timeout = 25.5MS + [25.5 MS* Handshake time].)
084 - PERMANENT BLK (Permanent Block)
Allows Lock (Parental Control) blocking schemes to be permanent
by disabling the blocking hours function. Set to 1 to install Parental
Control restrictions permanently. Set to 0 for user-specied hours
control of blocking schemes.
087 - REAR RGB EN. (Rear RGB Enable)
Controls access to rear RGB input on TV. Set to 0 to disable RGB
input. Set to 1 to enable RGB input. Set to 17 to initiate a one-
time automatic conguration after an AC power cycle; otherwise,
automatic adjustment will be performed each time the RGB input
is accessed.
088 - EN NOISE MUTE (Enable Noise Mute)
If set to 1, audio mutes when no signal is present.
090 - KEY LOCK
If set to 1, front keyboard Channel, Volume, and Caption buttons
are disabled, Power button remains enabled. If set to 0, Channel,
Volume, Caption, and Power buttons are all enabled.
091 - YPrPb2 EN. (HDMI2 Enable)
Set to 1 to enable display panel HDMI 2 input. Set to 0 to disable
display panel HDMI 2 input.
094 - SAP MENU EN (2nd Audio Program)
Set to 1 to enable SAP feature on Function menu, if Function
Menu is available (i.e., the TV is not in Pass-through Mode). Set
to 0 to disable SAP feature on Function Menu, if Function Menu is
available.
096 - DEF. ASP. RATIO (Default Aspect Ratio)
Selects default aspect ratio at power up.
Set to 0 for Set By System.
Set to 1 for 4:3.
Set to 2 for 16:9 (default).
Set to 3 for Just Scan.
Set to 4 for Zoom.
Note: This item is not available in the Installer Menu unless item
106 ASP RATIO LOCK is set to 0.
098 - PRO:CENTRIC
Selects the Pro:Centric Application Mode. Set to 0 (default) to dis-
able Pro:Centric operation. Set to 1 for Flash Mode. Set to 2 for
GEM (Java Application) Mode.
Note: This item is not available in the Installer Menu when item
119 DATA CHANNEL is set to 0.
099 - BACK LIGHTING
Sets the TV screen brightness at power up. Default setting is 255.
1 - 100 Static Back Lighting
(1 = Dimmest picture, 100 = Brightest picture)
101 - 200 Dynamic Back Lighting
(101 = Dimmest picture, 200 = Brightest picture)
The TV automatically controls back lighting depending upon the
picture level of the current program.
201 Automatic Static Back Lighting
The TV automatically controls back lighting depending upon
external spectral sensitivity.
202 Automatic Dynamic Back Lighting
The TV automatically controls back lighting depending upon
external spectral sensitivity and the picture level of the current
program.
If set to 255, back lighting is controlled via the Picture settings
in the TV setup menus.
102 - ATSC BAND
Sets up TV to receive different types of incoming signals:
0 = Broadcast, 1 = CATV, 2 = HRC, 3 = IRC, 4 = Same as NTSC.
103 - ATSC TUNE MODE
Sets ATSC tuning mode: Default set to 1 for Physical Channel
scan. Set to 0 for Virtual Channel scan.
104 - START MINOR CHANNEL
Sets Minor Start Channel number at power up. 0 = NTSC. If not
0, number selected is the digital channel’s Minor Start Channel
number.
Note: This item is not available in the Installer Menu when item
004 STRT CHANNEL is set to 0 or 255.
Installer Menu (Cont.)