Operative Information
When the three LEDs light up, they indicate the power, lamp or internal
temperature status or possible problems:
LED Indicator LEDs Display Description
Power
Indicator
Orange
Standby (The AC power switch is on,
and the projector is off.)
Blinking Green
When the power button is pressed, the
indicator blinks green until the LG logo
shows up.
Green The projector is working,
Blinking Orange
POWER-DOWN. It will cools down for
90 seconds after the power is turned off.
- Off (The AC power switch is off.)
Lamp
Indicator
Orange
The lamp has been in operation for over
1400 hours. The OSD message
“CHANGE LAMP, AND RESET LAMP
TIMER.” will be displayed on the screen
for 30 seconds.
Red
The lamp has been in operation for over
1500 hours. The OSD message “OUT
OF LAMP USAGE TIME. CHANGE THE
LAMP!” will be displayed on the screen
for 30 seconds.
Blinking Red
Something is wrong with the lamp power
supply. Please turn off the projector
within 3 seconds.
Temperature
Indicator
Red
The internal temperature of the projector
is too hot.
When the temperature inside the
projector is too high, the OSD message
“Temperature is too high. Going to shut
down.” will be displayed on the screen
for 10 seconds and then the projector
will automatically shutdown. The fans
will be continuing to run for 90 seconds,
then you can restart the projector.
Blinking Red
Something is wrong with the fans. The
OSD message “Fan or Diode error.
Going to shut down.” will be displayed
on the screen for 10 seconds, and then
the projector will automatically
shutdown. Please turn the projector off.