ix
3.2 Expansion of Device Range
For a list of the new device ranges see section 2.
Handling index registers
“V0” and “Z0” index registers are equivalent to registers “V” and “Z” respectively, so either one
can be used for programming.
When entering “V1” to “V7” or “Z1” to “Z7” add a numeral 1 to 7 to the “V” or “Z” before
pressing or .
3.3 Parameter setting
When a RUN terminal is needed on the PC, select “USE”, and specify an input number from
X000 to X017 (X000 to X007 only for FX
2N
-16M
and FX
2NC
-16M
).
Number of file register blocks
0 to 14 blocks can be specified for file registers. These occupy program space, 1 block = 500
program steps, and are stored with the program. File registers start at D1000.
SP
GO
MEMORY SETTING
2K 4K 8K 16K
Addition of 16K steps
RUN INPUT
USE X002
Setting of external RUN input
DON'T USE