Page 22
MODEL: WD-52531 / WD-62531 / WD-62530
4. Adjustment Selection
Use the “VIDEO” button to select a specific electrical adjustment, “1 HPOS” or “2 VPOS”.
5. Adjusting Data
After selecting an adjustment item, use the “UP” and “DN” buttons to change adjustment data.
• If the “UP” button is pressed, the adjustment data increases.
• If the “DN” button is pressed, the adjustment data decreases.
6. Saving data
Press “ENTER” to save the adjustment data in memory.
The display characters go red for approximately one second in this step.
Note: If the circuit adjustment mode is terminated without pressing
“ENTER”, changes in adjustment data are not saved.
7. Terminating the circuit adjustment mode
Press the “MENU” button on the remote hand unit twice to terminate the adjustment mode.
Note: The adjustment mode can be also terminated by turning the
power off.
Transferring Data
1) Enter the Service Adjustment Mode ... Press “MENU-2-4-5-7”
2) Press “0” when in the Service Mode ... Three choices appear at the top of the screen.
3) Use the UP & DN keys to highlight the desired choice, then Press “ENTER”
DATA TRANSFER
MENU-2-4-5-7-0
Display Description
Copy Engine E2PROM to DM After Replacing Engine or PWB-DM
Restore factory data Restores factory set values
DOWNLOAD WB ALIGNMENT TO FMT
Copies WB data from E2P to FMT
(after PWB-SIGNAL replacement)