MRV Communications EM316-2SFP Cable Box User Manual


 
EM316-2SFP User Guide
P/N 1259003-001 Rev C3 25
4.4.5 Chassis Context
4.4.5.1 Chassis Context – “show
The following CLI excerpt shows a Fiber Driver chassis system an EM316-2SFP module and
a EM316LNXNM-OT network management (NM) module. No other modules are installed in
this example.
Use the command line “?” (help character) to display command line parameters for the show
command.
Slot and port information examples are shown later in their own contexts. However, slot and
port information may be displayed directly from a “higher” context with the following
commands.
The command output for slot and port information is shown in the respective context
sections.
fiberdriver(chassis/1)#
s
how
Model: NC316BU-16
Name: NC316BU-1
Temp(C): 28
Temp Min(C): 5
Temp Limit(C): 55
PS1: not Installed PS2: AC Good
Fan1: bad Fan2: good
Fan3: good
Chassis Traps: on Slot Change Traps: on Module Specific Traps: on
Port Traps: on Link Traps: on Loopback Traps: on
LIN Traps: on Port Change Traps: on Port Diags Traps: on
Number Of Slots: 16
Hardware Revision: 1
Slot Model Name Serial Number
==== ============= ==================== ============================
1.1 EM316LNXNM-OT EM316LNXNM-OT at 1.1 00:20:1a:02:13:f1
1.2 EM316-2SFP EM316-2SFP at 1.2 N/A
----------------------------------------------------------------------
fiberdriver(chassis/1)#
Fiberdriver# show slots
Fiberdriver# show ports