Each module may be given a descriptive name with the command below. The show
command follows with the new name bolded.
4.4.6.4 “show digital-diagnostics
Many SFP transceivers support the digital diagnostics standards from SFF-8472. The
command below applies to ports with these SFP modules installed.
fiberdriver(slot/1.1)# show digital-diagnostics
Port DDiags Temp(C) Supply(V) TxPower(dBm) RxPower(dBm) BiasCurrent(mA)
===== ====== ======= ========= ============ ============ ===============
1.1.1 Ok 46 3.272 -5.066 -6.055 4.852
1.1.2 Ok 47 3.272 -6.053 -5.394 5.18
fiberdriver(slot/1.1)#
fiberdriver(slot/1.1)# description myslot1.1
fiberdriver(slot/1.1)# show
Slot: 1.1
Model: EM316-2SFP
Name: myslot1.1
Hardware Revision: 1
Sw Configurable: yes Operation Type: converter
Number Of Ports: 2
Port Enable Link LIN DDiags WL(nm) Name
===== ====== ============= ====== ====== ====== ============
1.1.1 enable signal Detect enable Ok 850 SFP-port1
1.1.2 enable signal Detect enable Ok 850 SFP-port2