43
11. SHARPNESS Gain Data
Function
The external control equipment changes the SHARPNESS gain data of the
plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H
DATA00 DATA01 DATA02
CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: SHARPNESS Gain Flag 06H
DATA02: SHARPNESS Gain F0H: -16
FFH: -01
00H: 0
01H: +01
10H:+16
ACK
7FH 60H 80H 7FH 02H
DATA00 DATA01
CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: SHARPNESS Gain Flag 06H
12. CONTRAST Gain Data
Function
The external control equipment changes the CONTRAST gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H
DATA00 DATA01 DATA02
CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: CONTRAST Gain Flag 07H
DATA02: CONTRAST Gain CCH: -52
FFH: -01
00H: 0
01H: +01
14H: +20
ACK
7FH 60H 80H 7FH 02H
DATA00 DATA01
CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: CONTRAST Gain Flag 07H
13. BRIGHT Gain Data
Function
The external control equipment changes the BRIGHT gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H
DATA00 DATA01 DATA02
CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: BRIGHT Gain Flag 08H
DATA02: BRIGHT Gain E0H: -32
FFH: -01
00H: 0
01H: +01
20H: +32
ACK
7FH 60H 80H 7FH 02H
DATA00 DATA01
CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: BRIGHT Gain Flag 08H
14. Input MODE Request
Function
The display returns the current input information by the external control
equipment’ s request.
Transmission Data
1FH 80H 60H 41H 00H CKS
ACK
7FH 60H 80H 41H 01H DATA00 CKS
DATA00: Input Select
01H: Video1 02H: Video2
03H: Video3 04H: HD (HD1 or DTV or DTV1)
05H: RGB1/PC1 06H: RGB2/PC2
0AH:DVD (DVD1) 0CH:HD2 (DTV2)
0DH:DVD2 0EH:RGB3/PC3
15. RESET
Function
The external control equipment resets the user adjustment of the plasma
monitor.
Transmission Data
1FH 80H 60H 54H 00H CKS
ACK
3FH 60H 80H 54H 00H CKS
16. COLOR TEMP SELECT
Function
The external control equipment changes the COLOR TEMP of the plasma
monitor.
Transmission Data
DFH 80H 60H 00H 01H DATA00 CKS
DATA00
00H: 1
01H: 2
02H: 3
03H: PRO
ACK
7FH 60H 80H 00H 01H DATA00 CKS
DATA00:
00H: 1
01H: 2
02H: 3
03H: PRO
NOTE: Set so that at the selection of 1, 2, or 3 of COLOR TEMP