Optoma Technology ES522RFBA Projection Television User Manual


 
English
60
Replacing the Lamp
The projection lamp should be replaced when it burns out. It should
only be replaced with a certied replacement part, which you can
order from your local dealer.
Important:
4
The lamp contains a certain amount of mercury and should be
disposed of according to local ordinance regulations.
4
Avoid touching the glass surface of the new lamp, doing so may
shorten its operation life.
Warning:
4
Be sure to turn off and unplug the projector at least an hour before
replacing the lamp. Failure to do so could result in a severe burn.
1. Loosen the two captive screws on the lamp compartment cover.
2. Remove the lamp compartment cover.
3. Remove the two screws from the lamp module.
4. Lift the module handle up and pull rmly on the module handle to
remove the lamp module.
5. Insert the replacement lamp and push down rmly. Tighten the
captive screws to hold the lamp in place.
6. Replace the lamp compartment lid and tighten the captive screws.
After replacing the lamp, the lamp hours counter must be reset. See
page 47 for more information.
Appendices