Orion Car Audio OE331-21 Universal Remote User Manual


 
1.)24 VAC Must Be Connected So
That All Ground Wires Remain
Common.
3.)All Communication Wiring To Be 18
Ga. Minimum, 2 Conductor Twisted
Pair With Shield. Belden #82760 Or
Equivalent.
4.)It Is Recommended That All
Controllers Address Switches Are
Set Before Installation.
2.)All Wiring To Be In Accordance With
Local And National Electrical Codes
and Specifications.
Line Voltage
All Communication Loop Wiring Is
Straight Through
24VAC
24VAC Transformer
10 VA Mini mum
GND
Local Loop RS-485
9600 Baud
Analog Inputs AIN1Thru AIN7
Can Be Used For 10kOhm
Type III Thermistor, 0-5VDC
Signal, 4-20mA Signal Or Dry
Contact Closure Inputs.
As Required.
Analog Input AIN6 Can Only Be Used
For Connection Of A Static Pressure
Transducer With Modular Connector
Connect To
Next Device On
The Local Loop
24VAC Power
For Relay Outputs
5 Relay Outputs Are
Available On Board For
On/Off Control Of
Equipment. When
Required 4 Additional
Relay Outputs Are
Available By Using The
Optional OE357 4 Relay
Output Expansion
Board. See Below.
Connect Tubing To High Pressure
Port (Bottom Tube) and Route To Static
Pressure Pickup Probe Located In Unit
Discharge. Leave Port Marked “Lo” Open
To Atmosphere
S.P.
Transducer
Splice If Req’d
Connect To
Expansion Board
Base (When Used)
4 Additional Relay Outputs
Are Available By Using The
OE357 4 Relay Output
Expansion Board. The
OE352 2 Slot Expansion
Base Board Is also
Required To Mount The
OE357 Board.
OE352 2 Slot Expansion Base Board
OE357
4 Relay Output
Board
Not Used
RLY1
D1
D2
D3
D4
D5
RAM
C3
C2
U6
PHILIPS
CX6
C1
CX2
U2
PAL
CX4
U4
TUC-5R PLUS
YS101816 REV. 2
V1
V2
V3
V5
V4
TB2
4
NETWORK
TOKEN
16
32
8
SW1
ADD
2
1
ADDRESS
V6
POWER
GND
24VAC
L1
D16
R6
C9
SC1
R11
U11
MC34064A
D13
C16
9936
VR2
TB4
R27
C13
R10
VR1
C19
C18
NE5090NPB3192
0PS
U8
CX8
U9
X1
R7
D10
R13
D12
C7
CX10
U10
CX12
U12
U14
CX14
PJ3
PJ2
PJ1
EXPANSION
PRESSURE
SENSOR
T'STAT
C17
D15
R26
C20
R25
R24
R22
U15
CX13
U13
C15
R19
R15
C14
D18
D17
PU1
PU2
PU3
PU4
PU5
PU7
D6
D7
D8
D9
D11
D14
C12
C10
0-5
VDC
0-1
VDC
JP1
C11
X2
GND
TB3
INPUTS
GND
GND
+VDC
AIN1
AIN2
AIN3
AIN4
AIN5
AOUT1
AOUT2
AIN7
RN4
1
RN5
RS-485
CX5
U5
R
TB1
SHLD
T
COMM
COMM
RN3
1
RN1
U1
CX1
1
LD6
COMM
PWR
LD7
LED1
LED2
LD9
LD8
R1
U7
RV1
VREF ADJ
R28
+VREF
5.11V
TEST POINT
EWDOG
D19
RN2
1
COM1-3
COM4-5
R5
R4
R3
R2
R1
RLY2
RLY3
RLY4
RLY5
CX15
(1 MEG)
HH
P1
C21
CX3
EPROM
U3
Warning:
24 VAC Must Be Connected So That All
Ground Wires Remain Common. Failure To
Do So Will Result In Damage To The
Controller
T To T, R To R, SHLD To SHLD
FILENAME
DATE:
DESCRIPTION:
PAGE
DRAWN BY:
GPC Plus Controller
1Of2
JOB NAME
G-GPC-PlusCNTRL1A.CDR
OE331-21-GPCPLUS
B. Crews
03/08/05
Note: When Using Sensors or
Transducers With 4-20 mA Input
Signal, The Pull-up Resistor For
The Input Being Used Must Be
Removed From The Controller
Board And A 250 Ohm Resistor
Must Be Wired Between The Input
Terminal And The Ground Terminal
On The Controller Board
Pull-up Resistor- Typical
Mini DIN Connector
For Connection Of Modular
Service Tool
OE331-21-GPCPLUS
GPC Plus Controller
VR5
MC
7824CT
C6
TB2
R14
D3
VR4
7812CT
MC
GND
+24VDC-OUT
+24VDC-OUT
GND
24VAC-IN
24VAC-IN
TB1
PWR
LD1
PJ2
C3
PJ1
2 SLOT MODULAR I/O2 SLOT MODULAR I/O
VR6
7824CT
MC
LM358N
YS101780
C4
C5
U2
VR1
R12
R6
CX2
R10
R4
R5
P2
JP2
UL 5A250VACUL 5A250VAC
G5L-114P-PS
OMRON
CONTACT:
24VDC
UL 5A250VAC
UL 5A250VAC
G5L-114P-PS
OMRON
CONTACT:
24VDC
UL 5A250VAC
UL 5A250VAC
G5L-114P-PSG5L-114P-PS
OMRON
CONTACT:
24VDC
UL 5A250VAC
UL 5A250VAC
G5L-114P-PSG5L-114P-PS
OMRON
CONTACT:
24VDC
K3
K2
4RLY IO BD.4RLY IO BD.
V4
K4
YS101790
TB1
V1
K1
K3
U2
K4
RN1
PCF8574P
U3
CX3
U1
ULN2803A/
K2
K1
74HC04N
P1
CX2
CX1
Jumper
Setting