Panasonic AJ-D450 VCR User Manual


 
– 39 –
Item Setting
No.
Superimposed
display
Description
No.
Superimposed
display
USER menu
508* TCG CF
FLAG
0000
0001
OFF
ON
This selects whether the CF flag of the TCG is to ON.
0:
1:
CF flag is OFF.
CF flag is ON.
507 PHASE
CORR
0000
0001
OFF
ON
This selects whether to control the phase correction of the
LTC generated by the TCG.
0:
1:
509 DF MODE 0000
0001
DF
NDF
This selects the DF/NDF mode for CTL and TCG.
0:
1:
No. 509 is valid when the CONTROL is LOCAL or LOCAL
ENA of item 004 to “ENA”.
Drop frame mode.
Non-drop frame mode.
<TIME CODE> (continued)
Phase correction control is not performed.
Phase correction control is performed.
510* RUN MODE 0000
0001
REC
FREE
This selects the time code generator run mode.
0:
1:
<Note>
Even if “0” is selected, the time code generator runs during
usual operation when “1” is selected at the setting menu
No. 504 (REGEN MODE).
Generator runs only during recording.
Generator runs during usual operation.
This selects whether to generate the internal black burst
signal.
0:
1:
This selects the component input signal level.
0:
1:
Signal is not generated.
Signal is generated.
Item Setting
No.
Superimposed
display
Description
No.
Superimposed
display
600* PB/PR
IN LV
0000
0001
M
II
B-CAM
601* INT BB
SIG
0000
0001
OFF
BB
MII level.
ß cam level.
<VIDEO>
This selects color killer processing for the video input signals.
0:
1:
602* INPUT
C KILL
0000
0001
B/W
AUTO
The signals are forcibly processed as B/W signals.
The signals are automatically processed.
This selects whether to float the vertical sync position of the
video output in order to align the video output phase with the
input in the EE/record/edit modes.
0:
1:
Signals are not floated.
Signals are floated.
603* OUT
VSYNC
0000
0001
N-VF
VF
511* TC OUT
REF
0000
0001
V OUT
TC IN
This is used to switch the phase of the time code, which is
output from the TIME CODE OUT connector, for the external
LTC input when the TC INT/EXT switch is at the EXT
position. (In EE mode only)
0:
1:
Time code is synchronized with output video signal.
Time code is synchronized with external time code input.
605 CC (F1)
BLANK
0000
0001
BLANK
THRU
This selects ON or OFF for the closed capture signal in the
first field.
0:
1:
Forced blanking performed.
Blanking not performed.
604 V-MUTE
SEL
0000
0001
N-MUTE
LOW
RF
This selects whether the video output signal is to be muted
when the blank portion of the tape is detected during
playback.
0:
1:
No muting (picture freezes).
Muting (picture turns grey).
The underline on the setting item denotes the initial setting.
* The Setup menu can
only be displayed for
the model AJ-D450.