Panasonic AJ-HD3700AP VCR User Manual


 
- 14 -
2K error messages
Message Error description
AJ-HDP2000
ALARM LED
2048 or 1920
LED
REF IN SIGNAL UNMATCH SYSTEM
FREQUENCY
There is a mismatch in frame frequency between
the SYSTEM set value and REF IN.
OUT OF RANGE OF SYSTEM PHASE BETWEEN
REF AND INPUT
There is a large phase difference between the
input signal and REF IN. (w/o OUTREF:
INPUT)
INPUT SIGNAL UNMATCH SYSTEM FREQUENCY There is a mismatch in frame frequency between
the SYSTEM set value and the input signal.
COMMUNICATION ERROR BETWEEN 2K
PROCESSOR AND HDD5
A communication failure occurs between
AJ-HDP2000 and AJ-HD3700B/A/H.
Check that the connection between AJ-HDP2000
and AJ-HD3700B/A/H is correct.
NO DUAL LINK CHA 2K INPUT There is no input signal to Dual-Link IN Ach.
The format of the input signals to Dual-Link IN
Ach is outside the specifications.
NO DUAL LINK CHB 2K INPUT There is no input signal to Dual-Link IN Bch.
The format of the input signals to Dual-Link IN
Bch is outside the specifications.
SUBSTANDARD TIMING DIFFERENCE IN DUAL
LINK 2K INPUT
The timing-phase difference of Dual-Link IN A/
Bch is outside the specifications (R 100 ns)
CRC ERROR IN DUAL LINK CHA 2K INPUT A CRC error occurs in signals on Dual-Link IN
Ach.
CRC ERROR IN DUAL LINK CHB 2K INPUT A CRC error occurs in signals on Dual-Link IN
Bch.
UNMATCH H SAMPLE BETWEEN INPUT SIGNAL
AND SYSTEM
There is a mismatch in H SAMPLE between the
SYSTEM set value and the input signal.
DUAL LINK CHA 2K ASSIGNMENT IS CHB On Dual-Link IN Ach, Bch is added to the
Channel Assignment information in PAYLOAD of
the input signals.
DUAL LINK CHB 2K ASSIGNMENT IS CHA On Dual-Link IN Bch, Ach is added to the
Channel Assignment information in PAYLOAD of
the input signals.
DUAL LINK 2K INPUT FORMAT ASSIGNMENT IS
NOT PsF
On Dual-Link IN A/Bch, the input signal format of
the PAYLOAD information is not PsF.
D_LINK 2K INPUT COLOR SPACE ASSIGNMENT
UNMATCH SYSTEM
On Dual-Link IN A/Bch, color space information
of the input PAYLOAD signals does not match
the SYSTEM settings for the unit.
* If any warnings are generated while ERR/FMT or ERR are set in TC/CHR menu F13
(EX SUPER), “2K PROC ERROR” is displayed on SUPER of the Monitor OUT output.
: Lighting
: Fast Flashing
: Flashing
: Flashing with some setting