Panasonic Generation Plasma Display Television Flat Panel Television User Manual


 
Standby Circuit
1. When the TV is connected to the AC line, the power supply outputs 5V.
2. This voltage is applied to the D board and the A board. The 5V applied to the D board in the
Panel Drive Section is not used during standby operation.
3. On the other hand, when the A board receives the 5V from the Power supply, it outputs the
“F_STB_ON” command.
4. This command is applied to the power supply board to generate the F_STB15V. The
F_STB15V is applied to the A board to energize the Signal SW/Process Circuit.
22