Panasonic Protocol Converter Manual V10.2 5Mar 09 Page 6/16
Internal view showing switches V12 Software
Data IN
2 WIRE
TRA TA
TRB TB
4 WIRE
TRA RA
TRB RB
RA TA
RB TB
Data OUT
TRA = A/+
TRB = B/-
SW5 Camera Range
RS232 DIAGNOSTICS PORT
12 3456 78
VCL - 9600,N,8,1
SW4 Output Protocol
12 3456 78
PELCO P – 9600,N,8,1
12 3456 78
PELCO P – 4800,N,8,1
12 3456 78
PELCO P – 2400,N,8,1
1 - 8
12 34
9 - 16
12 34
17 - 24
12 34
25 - 32
12 34
97 - 99
12 34
SW5/1-4 Camera range
SW5/8
Panasonic Baud
9600
8
19200
8
12 3456 78
DENNARD – 9600,N,8,1
33 - 40
12 34
41 - 48
12 34
49 - 56
12 34
57 - 64
12 34
65 - 72
12 34
73 - 80
12 34
81 - 88
12 34
89 - 96
12 34
12 3456 78
VICON – 4800,N,8,1
12 3456 78
VICON – 9600,N,8,1
LD1 = Dome RS422/485 out
LD2 = Panasonic RS422/485 in
LD3 = Checksum ERROR or
command for camera out of range
LD5 = Converter Mode
LD6 = Not used
Data OUT
TRA/TRB
Data OUT
TRA/TRB
Data OUT
TRA/TRB
Data OUT
TRA/TRB
Data OUT
TRA/TRB
Data OUT
TRA/TRB
Data OUT
TRA/TRB
Data OUT
TRA/TRB
ON
12345678
SW3
SW1 SW2
00007 -6
LD5
J16
SW4 SW 5
star_
v*.
vhd
PANA
CON
V**
ON
12345678
ON
12345678
ON
12345678
LD 1
LD 2
LD 3
LD6
LD4
SW3/8
ON = 2 WIRE
OFF = 4 WIRE
SD MICRO
Must be fitted
ON
12345678
12 3456 78