Panasonic PC8 TV Converter Box User Manual


 
Panasonic Protocol Converter Manual V10.2 5Mar 09 Page 8/16
VCL TP protocol
Function Panasonic Procedure
Program preset 1 – 32 As normal
Goto preset 1 – 32 As normal
Enable Privacy zone 100 – 127 Program preset 64
Followed by goto preset 1 – 28 (1 = zone 100)
Disable Privacy zone 100 – 127 Program preset 63
Followed by goto preset 1 – 28 (1 = zone 100)
Define Preset Patrol – START Program preset 62
Followed by 3 preset commands per preset position
PRESET NUMBER - GOTO PRESET 1-32
SPEED - GOTO PRESET 1-63, 64 = fastest
DWELL – GOTO PRESET 1-64 (x 2 seconds)
Define Preset Patrol – STOP Program preset 61
Start Preset Patrol AUTOPAN
Path 5 LEARN start PATROL LEARN or Program preset 60
Use joystick to move dome around required path
Path 5 LEARN stop PATROL STOP or Program preset 59
Path 5 PLAYBACK PATROL PLAY
Preset positions
The unit supports 32 preset positions per dome. Use the standard Panasonic method to
program a preset and also to goto preset.
Preset Tour 1
The dome’s preset tour 1 can be defined as follows
PROGRAM PRESET 62 : the converter is now waiting for 3 preset calls per position
GOTO PRESET 1-32 : this is the preset position that is being programmed
GOTO PRESET 1-64 : this is the speed, 1-63 are increasing speeds and 64 is maximum
GOTO PRESET 1-64 : this is the dwell in 2 seconds to stay at the preset position
PROGRAM PRESET 61 : this is the end of the tour definition
Example presets 1,2,8,16
PROGRAM PRESET 62 – start definition
GOTO PRESET 1 – preset position 1
GOTO PRESET 64 – maximum speed
GOTO PRESET 10 – 20 second dwell
GOTO PRESET 2 – preset position 2
GOTO PRESET 20 – slowish speed
GOTO PRESET 15 – 30 second dwell
GOTO PRESET 8 – preset position 8
GOTO PRESET 1 – very slow speed
GOTO PRESET 2 – 4 second dwell
GOTO PRESET 16 – preset position 16
GOTO PRESET 63 – fast speed
GOTO PRESET 1 – 2 second dwell
PROGRAM PRESET 61 – end definition