■ Camera Switching Pulse Loss
Display
• When loss of the camera switching pulse is detected,
“SW LOSS” will blink on the monitor screen.
• The buzzer does not beep.
• When the camera switching pulse is recovered, “SW
LOSS” is cleared from the monitor.
OTHER FUNCTIONS
The Video Multiplexer WJ-FS309/FS409 (WJ-FS316/FS416)
can be reset to the initial factory settings as follows.
1. Turn off the Power Switch.
2. Turn on the Power Switch (;) while pressing the ,
and buttons (WJ-FS309/FS409) or ,
and buttons (WJ-FS316/FS416). All LEDs light
up.
3. Resetting is completed when the buzzer stops beeping.
Note: Do not turn off the Power Switch until the buzzer
stops beeping.
MENU
ESC
13
12
MENU
ESC
5
4
ALL RESET
■ Channel Loss Alarm
Channel loss may occur initially after completing the setup
with the WJ-MP204. In this case, press the ALARM RESET
button. Channel loss can be avoided by setting CHANNEL
LOSS to OFF beforehand.
Operating the WJ-FS309/FS409 from the WV-CU360
System Controller
• When operating from the WJ-FS309/FS409, the menu
can be accessed without entering a password even if
PASSWORD is set to ON. Password entry is required
though to operate the Video Multiplexer from the
System Controller.
• To select a monitor from the WV-CU360, press 1 and
MON for Multiscreen output and 2 and MON for Spot
output.
• The ALARM SUSPEND function is not available on the
WJ-FS309/FS409, but can be accessed from the
Controller.