Panasonic WJ-FS409 Home Theater Server User Manual


 
39
Camera Switching Pulse Loss
Display
When loss of the camera switching pulse is detected,
SW LOSS will blink on the monitor screen.
The buzzer does not beep.
When the camera switching pulse is recovered, SW
LOSS is cleared from the monitor.
OTHER FUNCTIONS
The Video Multiplexer WJ-FS309/FS409 (WJ-FS316/FS416)
can be reset to the initial factory settings as follows.
1. Turn off the Power Switch.
2. Turn on the Power Switch (;) while pressing the ,
and buttons (WJ-FS309/FS409) or ,
and buttons (WJ-FS316/FS416). All LEDs light
up.
3. Resetting is completed when the buzzer stops beeping.
Note: Do not turn off the Power Switch until the buzzer
stops beeping.
MENU
ESC
13
12
MENU
ESC
5
4
ALL RESET
Channel Loss Alarm
Channel loss may occur initially after completing the setup
with the WJ-MP204. In this case, press the ALARM RESET
button. Channel loss can be avoided by setting CHANNEL
LOSS to OFF beforehand.
Operating the WJ-FS309/FS409 from the WV-CU360
System Controller
When operating from the WJ-FS309/FS409, the menu
can be accessed without entering a password even if
PASSWORD is set to ON. Password entry is required
though to operate the Video Multiplexer from the
System Controller.
To select a monitor from the WV-CU360, press 1 and
MON for Multiscreen output and 2 and MON for Spot
output.
The ALARM SUSPEND function is not available on the
WJ-FS309/FS409, but can be accessed from the
Controller.
OPERATING CONTROL OF SYSTEM UNITS (Supplementary)