Pelco DX8UP-512MBRAM DVR User Manual


 
2 C2612M-A (6/06)
Introduction
The following instructions serve as a guide for the installation of the DX8UP-512MBRAM memory expansion module.
PARTS LIST
Qty Description
1 512 MB double data rate (DDR) dual in-line memory module (DIMM)
1 Adhesive-backed upgrade part label
Figure 1.
512 MB DIMM Module
TOOLS NEEDED
1 Phillips-head screwdriver #1 (nonmagnetic)
1 Properly grounded ESD wrist strap and mat
4 Small containers for storing screws (optional)
Getting Ready
1. Familiarize yourself with the instructions throughout this manual.
2. Check that you have all the necessary parts and tools. Refer to the Parts List and Tools Needed sections.
3. Shut down the DX8000 Series DVR unit. Refer to DX8000 Installation Manual or Operations and Programming Manual for instructions on
shutting down your unit.
4. Unplug the power cord from the wall socket and then from the rear of the DVR.
Figure 2.
Removing Power Cord from Wall
WARNING:
For safety reasons, you must remove the power cord because current continues to flow through the DX8000 even when
the unit is off. Remove the power cord from the wall socket first and then from the rear of the DVR. It is critical that the unit be
unplugged for your safety.